Noise Enclosure Project (disregard the problems in the attachment – I just need help with the project)

 Please insert anything that I’m missing or something that was overlooked by me. The project is supposed to be a small motorcycle workshop, where sanding of metal parts, hammering of metal parts, and spray painting will be done.

Save Time On Research and Writing
Hire a Pro to Write You a 100% Plagiarism-Free Paper.
Get My Paper

General Ventilation Assignment

http://www.cdc.gov/niosh/npg/

. Page for reference.

1

Save Time On Research and Writing
Hire a Pro to Write You a 100% Plagiarism-Free Paper.
Get My Paper

. What is the evaporated volume, in ft

3

, of one quart of liquid toluene (at STP)?

2

. You know your process requires 20 liters of toluene during each 8-hour shift. All of this material is released into the workroom air. What is the generation rate, in mg/min?

3. The generation rate for a contaminant is 25 mg/min. The dilution volume flow rate is

4

,000 CFM. What is the equilibrium concentration of the contaminant in mg/m3?

4. A room measures 50’ x 30’ x 20’. The dilution volume flow rate is 3,000 CFM. At 8:00 am the concentration of a contaminant is 50 ppm. Assuming no additional contaminant is added to the workplace air, what will be the concentration of the contaminant at 8:00 pm?

5. With an initial concentration of 25 ppm and an equilibrium concentration of 300 ppm, if the time constant for the room is 90 minutes, what will be the concentration after 30 minutes?

6. Extra Credit for Complete Solution – This problem puts it all together. You are leaking one liter of methyl alcohol (methanol) every 3 hours. At the start of the day, you have a concentration of 50 ppm. Your room is 30’ x 20’ x 100’. The dilution volume flow rate is 4,000 CFM. What will be the concentration at the end of the day, 8 hours later?

No

ise Enclosure Project

Estimate the transmitted sound pressure level, SPL, with the noise barrier material in the bottom.

Equipment:

Hydraulic shaper machine

Paint Booth

Sandblasting

Description of Problem

Describe the problem requiring noise abatement.

Description of Barrier

Description of

Ventilation System

Ventilation System

Inlet fan (Direct drive motor)

Adopt big impeller turbo fan, 7.5KW, 380V, 50HZ, CE

Outlet fan (Direct drive motor)

No

Painting and baking exchange system

Solenoid valve+ pressure adjustment control cylinder driven damper exchange

Fan Capacity

25000m³ /h

Air Flow Speed

0.23 m/s in empty booth, 0.25— 0.35m/s in loaded booth

Estimated Noise Reduction

Using the data provided, estimate the reduction in noise that the containment is expected to provide. Can you describe (in words) what you are calculating. You may make up any data you wish to use.

Description of Barrier

ArtSeal Blankets and Acousti Curtains™ Acousti Curtain Sound Absorption Curtains and ArtSeal Blankets are quilted fiberglass composites that feature a durable vinyl coated fiberglass cloth facing quilted to two-inch thick fiberglass insulation. The ArtSeal Acoustical Sound Blankets are available in a variety of colors and stitch patterns. The standard size is a 4’ x 8’ curtain panel with custom sizes and die cuts available. They are used when you need to introduce sound absorption materials into hard reflective environments to reduce the reverberant noise energy in a room. Some typical uses include industrial plants, gymnasiums, auditoriums, and warehouses. The ArtSeal Sound Absorption Blankets are Class 1 fire-rated and have a sound absorption rating of .85.

Sample Data

Please use the data provided below. There is no contribution from octave bands not listed. There is no transmission loss for octave bands not listed in the data for the barrier material.

User 1

102.4

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

98.4

102.4

100.0

95.6

89.3

79.8

2

99.2

103.5

99.5

93.0

88.3

74.9

3

101.3

99.9

103.7

96.4

90.7

77.1

4

100.5

99.3

98.0

92.1

78.3

User 2

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

79.8

95.6

98.4

102.4

100.0

2

74.9

93.0

99.2

103.5

99.5

3

77.1

96.4

101.3

99.9

103.7

4

78.3

98.0

100.5

99.3

103.5

102.4

104.6

103.0

106.9

User 3

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

104.6

102.4

100.0

98.4

95.6

79.8

2

103.0

103.5

99.5

99.2

93.0

74.9

3

106.9

99.9

103.7

101.3

96.4

77.1

4

103.5

99.3

102.4

100.5

98.0

78.3

User 4

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

98.4

100.0

95.6

89.3

79.8

2

99.2

103.5

99.5

93.0

88.3

74.9

3

101.3

99.5

103.7

96.4

90.7

77.1

4

100.5

99.3

102.4

98.0

92.1

78.3

103.4

User 5

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

79.8

98.4

102.4

104.6

100.0

2

74.9

99.2

103.0

99.5

3

77.1

96.4

101.3

99.9

106.9

103.7

4

78.3

98.0

100.5

99.3

103.5

102.4

97.6

94.0

104.5

User 6

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

104.6

102.4

100.0

98.4

95.6

79.8

2

103.0

99.5

99.2

93.0

74.9

3

106.9

101.3

96.4

77.1

4

103.5

99.3

102.4

102.4

98.0

78.3

101.5

99.7

102.7

User 7

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

103.4

89.3

79.8

2

99.2

104.5

93.0

88.3

74.9

3

99.5

103.7

99.4

90.7

77.1

4

103.5

101.3

102.4

98.0

92.1

78.3

99.4

101.0

94.6

99.8

102.3

User 8

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

98.4

102.4

100.0

95.6

89.3

79.8

2

99.2

103.5

99.5

93.0

88.3

74.9

3

101.3

99.9

103.7

96.4

90.7

77.1

4

100.5

99.3

102.4

98.0

92.1

78.3

User 9

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

104.6

102.4

100.0

98.4

95.6

79.8

2

103.0

101.5

104.5

99.2

74.9

3

106.9

102.7

101.3

96.4

77.1

4

103.5

99.3

102.4

102.4

98.0

78.3

95.0

98.7

User 10

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

104.6

102.4

100.0

95.6

2

103.0

101.5

99.5

93.0

74.9

3

106.9

99.7

102.7

96.4

77.1

4

103.5

99.3

102.4

98.0

108.4

78.8

109.2

104.3

107.4

76.3

User 11

SPL per Octave Band in dBA

Location

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

1

104.6

102.4

100.0

98.4

95.6

79.8

2

103.0

101.5

99.5

99.2

93.0

74.9

3

106.9

99.7

102.7

101.3

96.4

77.1

4

103.5

99.3

102.4

102.4

98.0

78.3

Area of Project:

40 Feet20 Feet
Sand Blasting and
Hydraulic Shaper Machine
Paint Booth33 Feet7 Feet

40 Feet
20 Feet
Sand Blasting and
Hydraulic Shaper Machine
Paint Booth
33 Feet
7 Feet

Still stressed from student homework?
Get quality assistance from academic writers!

Order your essay today and save 25% with the discount code LAVENDER